Electromagnetic Clutches

These electromagnetic clutches require running in to obtain the rated torque values. To run the unit in you should engage and disengage the clutch several times at high speed but with the hydraulic system unloaded.

When fitting theclutch please clean the pulley carefully to ensure that no oil or grease is left on the pulley.

When fitting clutches with front driving flange check for correct coupling alignment.

Do not exceed the maximum rated torque as thiswould cause the clutch to slip and if this lasts for more than 5 seconds the coils would burn out.

No detailed specifications are available for this product.

There are no downloads for this product.

Code Description Model Max Torque daNm Max Speed RPM Mounting Flange For Pulley Diameter mm Voltage V Output Spline Spline Adaptor to suit Stock Price Quantity
30901-P-12 Electromagnetic Clutch Maximum Torque 9 daNm Gr. 1 & 2 Pumps 30901-P-12 9 2000 Group 1 or 2 Pump 153 12 V DC 35x31 DIN 5482 (Z.18) 18 tooth 10044 for group 2 pump 4mm key 10010 Group 1 pump 2.4mm key 1 in stock £341.08 (exc VAT)
30929-P-12 Electromagnetic Clutch maximum torque 14 12 V DC 30929-P-12 14 3000 Group 1 or Group 2 153 12 V DC 35x31 DIN 5482 (Z.18) 18 tooth 10044 for group 2 pump with 4mm key 10010 Group 1 pump with 2.4mm key Delivery in 52 working days. £382.88 (exc VAT)
30930-P-24 Electromagnetic Clutch maximum torque 14daNm 24V DC Gr. 1 & 2 30930-P-24 14 3000 Group 1 or 2 pump 153 24 V DC 35x31 DIN 5482 (Z.18) 18 tooth 10044 for group 2 pump with 4mm key 10010 Group 1 pump with 2.4mm key 1 in stock £382.88 (exc VAT)